Technical Specifications
AC OUTPUT |
Output
voltage: |
120 VAC
true sinewave
Optional 220 VAC |
Output
rating: |
250 VA, 150
watts continuous |
Output
voltage regulation: |
± 3.0%
static regulation of nominal
-10% to +4.0% dynamic |
Overload
surge capacity: |
300
watts surge for 5 seconds |
Output protection: |
Overcurrent
protection |
Harmonic
distortion: |
Less than 3.0% THD |
Output
frequency: |
60 Hz ± 0.5% crystal
controlled
Optional 50 Hz |
Operational
status |
LEDs and audible alarm |
DC INPUT |
Input voltage
selection: |
Nominal 12
VDC |
Input voltage
tolerance: |
10.5-15 VDC |
Input control/protection: |
2-pole
Guarded DC Circuit Breaker,
Under/Over voltage,
Input Reverse Protection,
Low Voltage Disconnect (LVD) protecting source so
vehicle battery does not go below starting voltage |
Input power
connection: |
Quick connect (1) NATO Slave female and
Quick connect
(1) Anderson Power Pole |
Input power
cable: |
Uses standard NATO Slave male-male cable or
Optional
10' Anderson to NATO Slave male connector |
DISTRIBUTION PANEL |
Output
circuits: |
Four outputs
standard |
Output protection: |
GFCI,
Ground Fault Circuit Interrupter |
Output
control: |
Optional panel switches or breakers
Optional remote interlock ON/OFF control |
Output
receptacles: |
NEMA 5-15R straight
blade standard |
Ground connection: |
Quick connect jack |
MECHANICAL |
Enclosure type: |
Mil Grade Briefcase,
water tight to -30 ft w/pressure relief valve, lockable |
Dimensions
( H x D x W ): |
6.1 in
(155 mm) x 12.2 in (310 mm) x 17.2 in (437 mm) |
Unit weight: |
10 lb.
(4.6 kg) with rugged,
folding lift handle |
Audible
noise: |
<47 dBA @ 5
ft., ANSI "A" scale |
Cooling
type: |
Positive pressure fan.
thermostatically controlled,
over temperature protection |
Air intake filter: |
Easy clean intake air
filter |
ENVIRONMENTAL |
Storage
temperature: |
-40° to
160° F ambient (-40° to 71° C),
lower/higher optional |
Operating
temperature: |
-25° to 140° F ambient (-32° to 60° C )
lower/higher optional |
Operating
humidity: |
0 to 95%
relative humidity,
non-condensing, higher optional |
Storage
elevation: |
Up to 40,000
ft (12,192 m) |
Operating
elevation: |
Up to 10,000
ft (3,048 m), higher optional |
STANDARDS |
United
States: |
Meets UL-1741
and 458 |
Canada: |
Meets CSA 107.1 safety
requirements |
International: |
Meets
EN60950-1 safety
requirements |
Electromagnetic
Compliance (EMC): |
EMI/RFI
FCC Part 15, Class B,
EN55022:1997, EN61000-3-2:1998,
EN61000-3-3:1995, EN550204:2001,
e-Mark e13-022025, Others optional |
OPTIONAL ACCESSORIES |
|
Input
Cables, Ground Cables w/ Clamp, Ground
Rod Kit, Power Distribution Units, Remote
Control/Monitor Panel |